Consumer
demand for high image quality from DLP™ based front projection systems
requires that manufacturers closely control a number of different image
parameters. These include display brightness, brightness uniformity,
contrast ratio (sequential black and white, and checkerboard), color,
color uniformity, distortion, gamma, focus, and gray scale. Detection
and quantification of blemishes and pixel level defects is also
important.
Traditionally,
this type of testing has been performed using either fixed arrays of
detectors, or by scanning a single spot photometer/colorimeter over the
image area. However, neither of these techniques fully meets the needs
of display manufacturers. For instance, the primary downside of a
scanned spot photometer/colorimeter is slow measurement speed. And
detector arrays, usually arranged in ANSI 9 or 13 point configurations
cannot identify image blemishes and pixel defects.
Radiant Imaging’s PM-PTS™ is a comprehensive, turnkey solution for measuring front projection display output parameters and identifying display defects. PM-PTS™ consists of a PM Series™ Imaging Colorimeter
mated to a specialized projection test software suite. This software
controls the pattern displayed on the projector, and performs
measurement and analysis of the measurement. This enables testing and
calibration to be fully automated. Most importantly, the PM-PTS™
utilizes a calibration light source to map the characteristics of the
projection screen or display surface, and then remove these screen
related factors from the projected image prior to analysis.
|